RESUMO
Real-time reverse transcription (rRT)-PCR, which is the reference standard for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, generally involves a time-consuming and costly RNA extraction step prior to amplification. We evaluated the performance of the AdvanSure One-Stop COVID-19 Plus Kit (LG Chem, Seoul, Korea), a novel rRT-PCR assay that can detect SARS-CoV-2 within 90 minutes using a streamlined RNA extraction method. In total, 509 nasopharyngeal swab (NPS) specimens (SARS-CoV-2 positive: N=205; SARS-CoV-2 negative: N=304) previously tested using the PowerChek SARS-CoV-2 Real-time PCR Kit (Kogene Biotech, Seoul, Korea) were tested using the AdvanSure assay. The limit of detection (LOD) of the AdvanSure assay was determined using serially diluted inactivated SARS-CoV-2. The positive and negative percent agreements between the AdvanSure and PowerChek assays were 99.5% (204/205) and 99.3% (302/304), respectively. The LODs of the AdvanSure assay for SARS-CoV-2 nucleocapsid and spike/RNA-dependent RNA polymerase genes were 672 and 846 copies/mL, respectively. The results show that the performance of the AdvanSure assay is comparable to that of the PowerChek assay used for routine SARS-CoV-2 testing, suggesting that the AdvanSure assay is a useful diagnostic tool for rapid and accurate detection of SARS-CoV-2 infection.
Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Teste para COVID-19 , RNA Viral/genética , RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e EspecificidadeRESUMO
Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) and influenza viruses may pose enormous challenges to our healthcare system. We evaluated the performance of the PowerChek SARS-CoV-2, Influenza A & B Multiplex Real-time PCR Kit (PowerChek; Kogene Biotech, Seoul, Korea) in comparison with the BioFire Respiratory Panels 2 and 2.1 (RP2 and RP2.1; bioMérieux, Marcy l'Étoile, France), using 147 nasopharyngeal swabs. The limit of detection (LOD) of the PowerChek assay was determined using SARS-CoV-2, influenza A, and B RNA standards. The LOD values of the PowerChek assay for SARS-CoV-2 and influenza A and B were 1.12, 1.24, and 0.61 copies/µL, respectively. The positive and negative percent agreements of the PowerChek assay compared with RP2 and RP2.1 were 97.5% (39/40) and 100% (107/107) for SARS-CoV-2; 100% (39/39) and 100% (108/108) for influenza A; and 100% (35/35) and 100% (112/112) for influenza B, respectively. The performance of the PowerChek assay was comparable to that of RP2 and RP2.1 for detecting SARS-CoV-2 and influenza A and B, suggesting its use in diagnosing SARS-CoV-2 and influenza infections.
Assuntos
COVID-19 , Influenza Humana , Humanos , Influenza Humana/diagnóstico , Nasofaringe , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2 , Sensibilidade e EspecificidadeRESUMO
The potential co-circulation of SARS-CoV-2, influenza, and respiratory syncytial virus (RSV) could pose an unprecedented challenge to healthcare systems worldwide. Here, we compared the performance of the PowerChek SARS-CoV-2, Influenza A&B, RSV Multiplex Real-time PCR Kit (PowerChek) for simultaneous detection of SARS-CoV-2, influenza A and B, and respiratory syncytial virus with that of BioFire Respiratory Panel 2.1 (RP2.1) using 175 nasopharyngeal swab (NPS) specimens. Positive percent agreement and negative percent agreement of the PowerChek assay compared to RP2.1 were as follows: 100 % (40/40) and 100 % (135/135) for SARS-CoV-2; 100 % (39/39) and 100 % (136/136) for influenza A; 100 % (35/35) and 100 % (140/140) for influenza B; and 93.1 % (27/29) and 100 % (146/146) for RSV, respectively. The limit of detection (LOD) was accessed using RNA standards for each virus, and the LOD values of the PowerChek assay for SARS-CoV-2, influenza A and B, and RSV were 0.36, 1.24, 0.09, and 0.63 copies/µL, respectively. Our results demonstrate that the PowerChek assay is sensitive and accurate for detection of SARS-CoV-2, influenza A and B, and RSV, suggesting that this assay can be a valuable diagnostic tool when SARS-CoV-2, influenza, and RSV are co-circulating.